← Back to search

Building permit

1925 N CLEVELAND AVE

PERMIT - RENOVATION/ALTERATION · Permit #101088645

Issued
Reported cost
$80,000.00
Ward
43

What’s happening here?

Water intrusion remediation; envelope upgrades

AI-generated summary · Verify against the description below.

Work description

SPR 2019 CBC: REVISION TO PERMIT # 101075545. DURING CONSTRUCTION, WATER INFILTRATION ISSUES WERE DISCOVERED DUE TO THE RESULT OF LESS-THAN-IDEAL CONSTRUCTION PRACTICES OF THE ORIGINAL CONSTRUCTION (NO AIR/WATER BARRIER OVER THE CMU AND EXPOSED WOOD TRUSS ENDS). THE WORK UNDER THIS PERMIT WILL BE TO ADDRESS THESE WATER INFILTRATION ISSUES BY REMOVING AND REPLACING THE EXISTING FACE BRICK (OTHER THAN ON THE NORTH FAÇADE) AND SEALING AND FLASHING THE STRUCTURAL CONCRETE MASONRY AND TRUSSES. TWO SINGLE WYTHE BRICK CHIMNEYS ENCLOSURES WILL BE REMOVED TO FURTHER IMPROVE THE BUILDING ENVELOPE WITH SLIGHT COMPOSITIONAL ADJUSTMENTS. THE TWO EXISTING VENTED WOOD/GAS FIREPLACES WILL BE REMOVED AND REPLACED WITH TWO VENTLESS GAS FIREPLACES. THE EXISTING REAR OPEN MASONRY PORCH WILL BE REBUILT IN KIND, MATCHING EXISTING CONDITIONS. (OCCUPANCY TYPE R-5, CONSTRUCTION TYPE IIIB)

Permit details

Permit ID
3461011
Permit type
PERMIT - RENOVATION/ALTERATION
Work type
Not provided
Milestone
INSPECTIONS
Review type
STANDARD PLAN REVIEW
Application started
Sep 17, 2026
Total fee
$1,877.00

Permit conditions

Not provided

Contacts

  • JORDAN & JAMIE FRIEDMAN

    OWNER OCCUPIED

    CHICAGO, IL, 60614

  • WHEELER, DANIEL HARDING

    ARCHITECT

    CHICAGO, IL, 60604

  • BURNHAM NATIONWIDE, INC.

    EXPEDITOR

    CHICAGO, IL, 60602-

  • LG COMMERCIAL LLC

    CONTRACTOR-GENERAL CONTRACTOR

    CHICAGO, IL, 60654

  • SOLVE CONSTRUCTTION INC

    MASONRY CONTRACTOR

    ADDISON, IL, 60101-

View source data

Original City of Chicago permit record.

{
  "id": "3461011",
  ":id": "row-fd66_kdzn.vuzy",
  "ward": "43",
  "permit_": "101088645",
  "latitude": "41.91724205860119",
  "location": {
    "type": "Point",
    "coordinates": [
      -87.641066853345,
      41.917242058601
    ]
  },
  "pin_list": "1433306013",
  "longitude": "-87.64106685334454",
  "total_fee": "1877",
  "issue_date": "2026-10-20T00:00:00.000",
  ":updated_at": "2026-10-26T22:33:00.268Z",
  "permit_type": "PERMIT - RENOVATION/ALTERATION",
  "review_type": "STANDARD PLAN REVIEW",
  "street_name": "CLEVELAND AVE",
  "xcoordinate": "1172660.9678724655",
  "ycoordinate": "1913193.3010943208",
  "census_tract": "71600",
  "permit_status": "ACTIVE",
  "reported_cost": "80000",
  "street_number": "1925",
  "subtotal_paid": "1877",
  "community_area": "7",
  "contact_1_city": "CHICAGO",
  "contact_1_name": "JORDAN & JAMIE FRIEDMAN",
  "contact_1_type": "OWNER OCCUPIED",
  "contact_2_city": "CHICAGO",
  "contact_2_name": "WHEELER, DANIEL HARDING",
  "contact_2_type": "ARCHITECT",
  "contact_3_city": "CHICAGO",
  "contact_3_name": "BURNHAM NATIONWIDE, INC.",
  "contact_3_type": "EXPEDITOR",
  "contact_4_city": "CHICAGO",
  "contact_4_name": "LG COMMERCIAL LLC",
  "contact_4_type": "CONTRACTOR-GENERAL CONTRACTOR",
  "contact_5_city": "ADDISON",
  "contact_5_name": "SOLVE CONSTRUCTTION INC",
  "contact_5_type": "MASONRY CONTRACTOR",
  "other_fee_paid": "1200",
  "contact_1_state": "IL",
  "contact_2_state": "IL",
  "contact_3_state": "IL",
  "contact_4_state": "IL",
  "contact_5_state": "IL",
  "processing_time": "33",
  "subtotal_unpaid": "0",
  "subtotal_waived": "0",
  "zoning_fee_paid": "75",
  "other_fee_unpaid": "0",
  "other_fee_waived": "0",
  "permit_milestone": "INSPECTIONS",
  "street_direction": "N",
  "work_description": "SPR 2019 CBC: REVISION TO PERMIT # 101075545.  DURING CONSTRUCTION, WATER INFILTRATION ISSUES WERE DISCOVERED DUE TO THE RESULT OF LESS-THAN-IDEAL CONSTRUCTION PRACTICES OF THE ORIGINAL CONSTRUCTION (NO AIR/WATER BARRIER OVER THE CMU AND EXPOSED WOOD TRUSS ENDS).   THE WORK UNDER THIS PERMIT WILL BE TO ADDRESS THESE WATER INFILTRATION ISSUES BY REMOVING AND REPLACING THE EXISTING FACE BRICK (OTHER THAN ON THE NORTH FAÇADE) AND SEALING AND FLASHING THE STRUCTURAL CONCRETE MASONRY AND TRUSSES. TWO SINGLE WYTHE BRICK CHIMNEYS ENCLOSURES WILL BE REMOVED TO FURTHER IMPROVE THE BUILDING ENVELOPE WITH SLIGHT COMPOSITIONAL ADJUSTMENTS. THE TWO EXISTING VENTED WOOD/GAS FIREPLACES WILL BE REMOVED AND REPLACED WITH TWO VENTLESS GAS FIREPLACES.   THE EXISTING REAR OPEN MASONRY PORCH WILL BE REBUILT IN KIND, MATCHING EXISTING CONDITIONS.  (OCCUPANCY TYPE R-5, CONSTRUCTION TYPE IIIB)",
  "building_fee_paid": "602",
  "contact_1_zipcode": "60614",
  "contact_2_zipcode": "60604",
  "contact_3_zipcode": "60602-",
  "contact_4_zipcode": "60654",
  "contact_5_zipcode": "60101-",
  "zoning_fee_unpaid": "0",
  "zoning_fee_waived": "0",
  "other_fee_subtotal": "1200",
  "building_fee_unpaid": "0",
  "building_fee_waived": "0",
  "zoning_fee_subtotal": "75",
  "building_fee_subtotal": "602",
  "application_start_date": "2026-09-17T00:00:00.000"
}