Building permit
7816 S KILBOURN AVE
PERMIT – EXPRESS PERMIT PROGRAM · Permit #B100894428
- Issued
- Reported cost
- $3,775.00
- Ward
- 18
What’s happening here?
Move main electrical service panel
AI-generated summary · Verify against the description below.
Work description
ESC: NEEDED PRE-ESC: NOT ALLOWED BFEED REQ'D: 40A METER/SERVICE: SOCKET/OVERHEAD PANEL: GE 100 (NO MAIN BREAKER) SERVICE CONDUCTORS TAPPED TO BUS RECOMMENDED INTERCON: SUPPLY TAP MAIN SERVICE PANEL IS LOCATED ABOVE GAS STOVE SCOPE RELOCATED MAIN SERVICE PANEL TO A CODE COMPLIANT LOCATION. RUN SERVICE ENTRY CONDUIT TO NEW PANEL. IF THE NEW PANEL LOCATION IS NOT WITHIN 5 FEET OF THE METER THEN INSTALL A 100A DISCONNECT WITH 5 FEET OF THE NEW PANELS LOCATION (EITHER INSIDE OR OUTSIDE) INSTALL A NEW JUNCTION BOX WHERE THE EXISTING PANEL WAS AND SPLICE AND REDIRECT BRANCH CIRCUITS TO THE MAIN SERVICE PANEL. ENSURE BONDING AND GROUNDING ARE UP TO CODE. BOND THE COLD WATER MAIN. AHJ CHICAGO GOVERNING ELECTRICAL CODE 2018 CHICAGO ELECTRICAL CODE
Permit details
- Permit ID
- 3148604
- Permit type
- PERMIT – EXPRESS PERMIT PROGRAM
- Work type
- Electrical Work
- Milestone
- COMPLETE
- Review type
- EXPRESS PERMIT PROGRAM
- Application started
- Oct 6, 2020
- Total fee
- $75.00
Permit conditions
Not provided
Contacts
-
VIVINT SOLAR DEVELOPER,LLC,
ELECTRICAL CONTRACTOR
WHEELING, IL, 60090
-
STAUFFER DONALD
APPLICANT
WHEELING, IL, 60090
-
VININT SOLAR DEVELOPER, LLC
APPLICANT
WHEELING DR, IL, 60090
View source data
Original City of Chicago permit record.
{
"id": "3148604",
"ward": "18",
"permit_": "B100894428",
"latitude": "41.75053713258369",
"location": {
"type": "Point",
"coordinates": [
-87.734288306984,
41.750537132584
]
},
"longitude": "-87.73428830698417",
"total_fee": "75",
"work_type": "Electrical Work",
"issue_date": "2020-10-06T00:00:00.000",
"permit_type": "PERMIT – EXPRESS PERMIT PROGRAM",
"review_type": "EXPRESS PERMIT PROGRAM",
"street_name": "KILBOURN AVE",
"xcoordinate": "1147712.8325720453",
"ycoordinate": "1852255.7674768437",
"census_tract": "700200",
"permit_status": "COMPLETE",
"reported_cost": "3775",
"street_number": "7816",
"subtotal_paid": "75",
"community_area": "70",
"contact_1_city": "WHEELING",
"contact_1_name": "VIVINT SOLAR DEVELOPER,LLC,",
"contact_1_type": "ELECTRICAL CONTRACTOR",
"contact_2_city": "WHEELING",
"contact_2_name": "STAUFFER DONALD",
"contact_2_type": "APPLICANT",
"contact_3_city": "WHEELING DR",
"contact_3_name": "VININT SOLAR DEVELOPER, LLC",
"contact_3_type": "APPLICANT",
"other_fee_paid": "0",
"contact_1_state": "IL",
"contact_2_state": "IL",
"contact_3_state": "IL",
"processing_time": "0",
"subtotal_unpaid": "0",
"subtotal_waived": "0",
"zoning_fee_paid": "0",
"other_fee_unpaid": "0",
"other_fee_waived": "0",
"permit_milestone": "COMPLETE",
"street_direction": "S",
"work_description": "ESC: NEEDED PRE-ESC: NOT ALLOWED BFEED REQ'D: 40A METER/SERVICE: SOCKET/OVERHEAD PANEL: GE 100 (NO MAIN BREAKER) SERVICE CONDUCTORS TAPPED TO BUS RECOMMENDED INTERCON: SUPPLY TAP MAIN SERVICE PANEL IS LOCATED ABOVE GAS STOVE SCOPE RELOCATED MAIN SERVICE PANEL TO A CODE COMPLIANT LOCATION. RUN SERVICE ENTRY CONDUIT TO NEW PANEL. IF THE NEW PANEL LOCATION IS NOT WITHIN 5 FEET OF THE METER THEN INSTALL A 100A DISCONNECT WITH 5 FEET OF THE NEW PANELS LOCATION (EITHER INSIDE OR OUTSIDE) INSTALL A NEW JUNCTION BOX WHERE THE EXISTING PANEL WAS AND SPLICE AND REDIRECT BRANCH CIRCUITS TO THE MAIN SERVICE PANEL. ENSURE BONDING AND GROUNDING ARE UP TO CODE. BOND THE COLD WATER MAIN. AHJ CHICAGO GOVERNING ELECTRICAL CODE 2018 CHICAGO ELECTRICAL CODE",
"building_fee_paid": "75",
"contact_1_zipcode": "60090",
"contact_2_zipcode": "60090",
"contact_3_zipcode": "60090",
"zoning_fee_unpaid": "0",
"zoning_fee_waived": "0",
"other_fee_subtotal": "0",
"building_fee_unpaid": "0",
"building_fee_waived": "0",
"zoning_fee_subtotal": "0",
"building_fee_subtotal": "75",
"application_start_date": "2020-10-06T00:00:00.000"
}